Day: February 16, 2017

INCINERATEUR DE DECHETS HOSPITALIER hospital incinerator design SPECIFICATIONS TECHNIQUES. Capacité destructive de 55 Kg/h jour de déchets hospitaliers  avec un p?.c. i jusqu’à 3.200 Kcal/Kg 1)Type de déchet hospitalier 2)Pouvoir calorifique inférieur                                                                        3.200 kcal/kg 3)Humidité                                                                                                          20% 4)Teneur  en cendres et/ou inertes                                                                       8% 5)Capacité destructive nominale                                                                         55 kg/h 6)Volume chambre de combustion                                                                     1,65 m3 7)Volume chambre […]
Our normal activities generates 2-5 tons of assorted waste materials per day which range from condemned carcasses, and medical incinerator primary combustion price other wastes all which need to be incinerated at above 800Centigrade measured flue exhaust gas.To be used by small hospitals and clinics to safely dispose of infectious and pathological wastes. Load Capacity […]
Capacity    Not less than 500Kg/hr. Operation    24hr-7days/week continuous operation. Combustion chamber    2 combustion chamber. Temp.    First combustion chamber 800-1000 C. Secandry combustion chamber 1000-1200 C, with the possibility to be upgraded to 1400 C. Combustion Efficiency    99.99% Retention time    Of the flow gases not less than 2 Sec in the hot portion. Excess Oxygen concentration   […]
1    Basic Plant Design    An approved plant must have four distinct sections that demonstrate three principles of Turbulence, Residence Time and Temperature are inbuilt in the plant design .The regulated sections may include but not limited to: Overall plant layout. Feed chamber/ charging Primary Combustion Chamber. Secondary Combustion Chamber. Particulate Scrubbers Acid Gas Scrubbers The […]
the following containerized incinerators. (Kitchen and accommodation and grey water and black water plant removing waste) we need incinerator is each function separate are all in one incinerator we need informed. Plant we installing for our accommodation barge used in an offshore marine construction project. 200 People would be accommodated onboard. WASTE INCINERATORS RECOMMENDATIONS china […]
waste incinerator manufacturer china, Waste chamber Chamber capacity 300 kg Chamber volume .54m3 Chamber size (outside) Width: 91cm, Height: 86cm Length: 152cm Door opening 66 x 76 cm Height to door 84 cm Height to top of stack 5.4 m Suggested slab size (L x W x Thickness) 1.8 m x 2.4 m x 10 […]
RECYCLABLE WASTE    PLASTIC (NON-PVC)     218,693 CARDBOARD     85,046 PAPER     4,956 PVC     15,115 HAZARDOUS WASTE    MEDICAL WASTE     1,084 SOLID WASTE CONTAMINATED WITH HYDROCARBONS     300,680 USED ENGINE OIL FILTERS     85,423 HYDROCARBON-CONTAMINATED SOILS     88,680 ORDINARY WASTE    FIBERS     14,078 USED AIR FILTERS (AUTOMOTIVE AND SIMILAR)     23,149 PERSONAL PROTECTIVE EQUIPMENT (PPE), […]
Technical specification for burning machine,animal waste incinerator manufacturer 1.Two systems are required to be installed in the south of the Kingdom of Saudi Arabia. The two systems will be used by custom authority to burn different kinds of drugs. All need equipment must be provided. 2.Warrantee:  booth systems must be provided with 3 years warrantee […]
medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: – ·         Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste ·         Waste density: 125 to 350Kg/M3 ·         Waste CV: 4000 KCAL/kg ·         Moisture content: 10-25% ·         Estimated ash residue: 5-10% ·         Nominal […]
In a simple design with a metal steel drum electric. including: A cage for receipt of biomedical waste; A combustion chamber with fireplace with a filter to retain ashes; A cover; An air supply; A turbine  allowing the supply of the air. Combustion temperature: 1800 ° C. Compliance with European standards. Comes with all necessary […]