Day: October 11, 2017

Stack: Type:  Wire Supported MOC:  Mild Steel of ISstd Height :3 Meters or more • PROCESS AT LEAST 1 METRIC TON OF WASTE PER DAY • OPERABLE BY 1 PERSON, WITH NO TRAINING REQUIRED • REGULAR MAINTENANCE CAN BE COMPLETED BY 1 PERSON WITH LIMITED TRAINING • REGULAR MAINTENANCE SHOULD NOT EXCEED 1-HOUR PER DAY […]
Primary Combustion Chamber Waste Charging Door: Provided with refractory lining with sealing gaskets Ash Removed Door: Provided with refractory lining with sealing gaskets Outer Body MOC: Mild Steel, 5mm Primary Chamber: Stainless Steel Operating Temperature :800. ± 50◦C Insulation: Insulation Brick Heating Elements Type: Kanthal Al Grade Power Consumption: 75 KW ( Initial Load ) […]
1. Is the residence time more than 2 seconds? 2. Is the primary and secondary air preheated? 3. Could it be provided as a continuous system? 4. Is there a monitoring system for operational parameter? (temperature) 5. Is there a data logging system? 6. Does it provide for control interventions to adjust waste feed, grate […]
Burning rate: 250 Kg/hr. It should be able to Operate not Less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… Design Specification: Types A, B, C, D, and E of medical waste “PYROLYTIC” combustion, by controlling the gasification of waste. The incinerator […]
GOODS:  ONE INCINERATORS IN ACCORDANCE WITH THE   SUPPLIER’     REQUIREMENT   S OWN           PROPOSED                     SPECIFICA           TION/             CONFIRM           ATION         […]
GOODS:  ONE INCINERATORS IN ACCORDANCE WITH THE   SUPPLIER’     REQUIREMENT     S OWN             PROPOSED                         SPECIFICA             TION/               CONFIRM         […]
TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals   INTRODUCTION All the incinerators to be supplied and installed must meet the Government of Kenya waste Management Regulation 2006 in particular 3rdschedule regulation (26, 47) pertaining classification, standards, criteria, and procedure for installing/operating incinerators as authored by the National Environmental Management and Coordination (waste management) regulation 2006, legal […]
1) Policy – Waste disposal management shall be taken special note to prevent hospital infection. – Infections wastes shall be managed, stored strictly and burned by a incinerator located at hospital site.   2) Waste Disposal Plan a)Classification – Medical wastes in hospital are classified as follows;   Infections Waste Specially-controlled waste Organ, needle, etc. Industrial waste […]