use in the hospital for burning hazardous waste and chimicals, minimum Capacity 300 per hour. I will be reselling to my client?. Below is the information I was given and nothing else. The hospital incinerator for use in the clinical waste as required by international environmental management. Minimum 300 Kg capacity/hr, Fuel fired, refractory lined, […]
Recently one of clients informed us their intention to procure 1 unit Gas Incinerator.medical waste incinerator to burn the wastes of hospitals in Egypt , the capacity required is 5 tons per day.the medium incinerator that uses both electricity and oil.A SMALL PET CREMATORY WITH GAS
1- There are more than 4000 Cubic Meter sludge are packed in Plastic Bags & stored more than 10 years 2- Cleaning and treated 2500 Cubic Meters inside the Oil Tank. – the waste is biological and coming from lab, can be heavily hazardous in case of terror attack or epidemics or similar events. – […]
Medical Waste treatment unit The medical waste treatment unit shall be environmentally-friendly, and have a capacity of about 200-300kg per batch , to enable treatment of medical waste generated in a 160-bed hospital The equipment should be self-steam generating if steam is needed for the sterilization process. The medical waste treatment unit shall be capable […]
Items/Model TS50(PLC) Picture Principle Medical Waste Incineration,dual chamber incinerator Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) average 16.9 Gas Consumption (m3/hour) average 20.2 Temperature Monitor Digital Display Temperature Protection Yes […]
Items/Model TS50(PLC) Picture Principle Medical Waste Incineration Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Gas Flue Washing System incineration of medical waste Feed Mode Manual Voltage 220V Power 4.0 Kw Oil Consumption (kg/hour) average 16.9 Gas Consumption (m3/hour) average 20.2 Temperature Monitor […]
Items/Model TS500(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 500 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700Liters (2.7m3) Internal Dimensions 190x120x120cm Secondary Chamber 1300Liters (1.3m3) Smoke Filter Chamber Dry Scrubber Chamber Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (kg/hour) Average 44(DO) Gas Consumption (m3n/hour) Average 53(NG) Temperature Monitor Digital […]
Item Specification Model YD-20C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters Optional: Mobile Trailer for Incinerator Mobile Type Incinerator Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 1. Incinerator 10kg per hr 2. Incinerator 20kg per hr 3. Incinerator 50kg per hr 4. Incinerator 100kg per hr 5. INDOOR INCINERATOR HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration […]
Items/Model TS800 Picture Principle Animal Waste Incineration Treatment Burn Rate Average 300-450 kg/hour Feed Capacity Average 1200kg/feeding Control Mode Electric Control Combustion Chamber 3000Liter Internal Dimensions 300*100*100 cm Secondary Chamber *** Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) ***waste to energy plants cost Gas Consumption (m3/hour) Ave.22.8m3n/hr Temperature Monitor Digital Display Temperature Protection Yes […]