Blog

Medical Waste Incinerator, 50 to 60 Kg/hrSupport Health Sector Support ProjectPoint of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals1.    General DescriptionSupply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment.  The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006).  The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.  The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour.  It shall be constructed from mild or aluminized steel lined with refractory material.Main unit Application For incineration, general and pathologicalCapacity   50 C 60 kg/h burn rateType Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unitOperating time                Minimum 8 hours dailyOperating temperature     From 850 0C to 1200 0C, Automatic controlledResidual Ash                    5 to 10%    3.2     Primary ChamberConstruction Constructed from heavy duty mild or aluminized  steel Orequal and approved equivalentInsulation material            Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickworkInternal Construction        Fixed hearth type complete with gratings, concave bottomand charging door, lined with refractory materialCharging Door                   Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges.Door Lock                          Automatic, Electric typeAsh removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamberGratings   ProvidedLoading Manual loading of wastePrimary Burner                        Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure,  Diesel fired fuel injector type and Flange mounted                                                                                                    Blower Provided. For supplying excess combustion air through the distribution system with speed control systemTemperature Minimum exit 850 0CObservation port To be provided with protective glass typeConstruction   Constructed from heavy duty mild or aluminized steel or equal and approved equivalentInsulation Refractory material liningCombustion Temperatures        Above 850 0C, controlled electronicallyGas residue or retention Time       > 2 second at minimum 850 0CSecondary Burner                    Provided, Diesel fired, fully automatic, with fuel, temperature and speed controls, With ignition system,                                                                  Flame detector, Air fan, Complete with safe ty features, flame failure Diesel fired fuel injector type.                                                                  Flange mountedEjector Provided, Venturi type, for cooling the flue gasesCombustion Air Fan Provided for supplying combustion and creating a negative drift and turbulencesTemperature Maximum  1600 0C
Сжигать: медицинские отходы, а также основные отходы. Способность плавить отходы: 400-500кг / час. Газ: Дизель. Впуск газа: оптимально 10 л / час. Температура сжигания: 950-1300 градусов по Цельсию. Корпус: толстое (мин. 5 мм) покрытие из нержавеющей стали, а также полностью защищено. выдерживает воздействие влаги в море. Напряжение 220/240 В или 380/415 В. Регулярность 50 Гц. […]
HS Code for waste incinerator 84178050 Item Specification Model TS100 PLC Main Product List per 01 set Primary Combustion Chamber   Secondary Combustion Chamber   Smoke Filter Chamber   Incinerator PLC Control Case   Chimney:10.0Meters *(upgrade to Stainless Steel, free cost)   Italy oil/gas burner: 02 units   Oil Tank (if oil fuel): 200Liters   […]
contaminated materials high temperature burners for the treatment of contaminateds materials. The waste will definitely be blended, including medical, oily wastes, woods as well as lab wastes. Key burning Diesel/LPG/LNG burning primary burning chamber/primary burning location Extra burning House time in the second chamber very little less than 2 secs Both primary and also the […]
MEDIUM-CAPACITY ANIMAL CARCASS INCINERATOR HICLOVER Model TS100(PLC) with wet scrubber optional Items/Model TS100(PLC) Picture   Principle Waste Incineration Treatment(Poultry and dead fish Incinerator Machine) Burn Rate Average 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 970L Internal Dimensions 120x90x90cm Secondary Chamber 480L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V-240V Power 0.7Kw […]
El incinerador también estará equipado con dispositivos de carga especiales y mecanismos que permitan la incineración segura de residuos sólidos simultáneamente con lodos líquidos. La carga de residuos sólidos se puede lograr a través de bolsas. Todas las tuberías intermedias, fuelles y otros accesorios para la conexión entre los tanques. , el quemador, el compresor […]
дизельная горелка для медицинских отходов Цена сжигания: 47,5––50 кг / час. Минимальная рабочая температура: 850 o C (ключевое горение). Оптимальный уровень рабочей температуры: 1450 oC (камера дожигания). Вторичная горящая способность: обязательная. Толщина изоляции: 20 мм. Огнеупорное литье: минимум 65 мм. Прочная преломляющая футеровка, выдерживающая: 1500 oC. Типичное время выгорания: максимум: 3 человеческих ресурса. Тип топлива: […]
Single and also Double Chamber Medical Incinerator.durable and incredibly dependable burners with numerous capacities for hospital/medical waste, cremation in addition to numerous other solid waste therapies. Chamber Dual Burning Rate 10 kg per hour (for 2 incinerators) Burning Price 20 kg per hr (for three heaters) Packing Method Manual No of Burners Solitary for 10 […]
Q: what is kind of waste can use in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. Items/Model TS30(PLC) Burn Rate Average 30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L […]
Patients with this debilitating virus produce 440 gallons of medical waste daily, including instruments, gowns, gloves, body fluids, sheets, mattresses and more. That’s a substantial amount of medical waste in any situation, but it’s especially daunting in this case because it needs to be disposed of extremely cautiously, to avoid the risk of spreading infection. […]