Blog

Waste calorific value: 4000KCAL/KG Wetness Web content: 10-25%. Nominal Capability: 50Kg/Hour batch load. Secondary Chamber: 2 Secs @ 850degrees C. The main combustion chamber should ensure minimal departure temperature level is not less than 850 degrees C. INSULATION. Calcium Silicate. Restricting Continuous service restriction 1000 degrees C. Thickness 25mm THROUGHPUT. 50kg/hour at a small calorific […]
Инсинератор для утилизации медицинских отходов со следующими характеристиками: • При высоких температурах (двухкамерный пиролитический инсинератор с температурой от 950 ºC до 1320 ºC; • Способность к разрушению от 400 до 600кг в час; • Способен уничтожать микроорганизмы; • Слить золу; • Сливная игла и дробилка для стекла; • Крыльцо с водопроводной водой для мытья рук […]
tipo estándar, 11 m de largo, autoportante Capacidad-220kgs / hr residuos hospitalarios humedad promedio-15-20% en el primer tiempo DIMENSIONES altura: 2710mm longitud: 2840mm Ancho; 2450 mm Apertura de la puerta de carga: 610 mm x 610 mm Área de rejilla / Heath: 2.0 (metros cuadrados) Volumen de la cámara primaria: 2,4 (metros cúbicos) volumen de […]
Huge incinerators – – INDUSTRIAL INCINERATORS – – specs below. 2.) Dimension need for the burners is 750 — — 850 kg capability 3.) The bum rate need to be 80 LL 100 kg/ hour. 4) The key chamber shouId have an operating temperature level of 900 -1200 degree C. 5) The incinerator must despise […]
Модель CA-200 Картина Скорость горения В среднем 100 кг / час Первичная камера сгорания 2000 литров Дымоход вторичного сгорания да Режим подачи Руководство по эксплуатации Напряжение 220В Мощность 3,0 кВт Тип топлива Дизельное топливо Горелка Италия Оригинал Расход масла (дизельное топливо) В среднем 53 кг /час Внутренние размеры 230 х 100 х 90см (первичная камера) […]
Snap Lake Mine, 220 kilometres northeast of Yellowknife, where elevated levels of dioxins and furans were pumped into the air. | Photo Fire Prevention Services Last July, two incinerators at De Beers’ Snap Lake Mine were belching out clouds of black smoke, one sending an average of 65 times the accepted national limit of cancer-causing […]
Supply, setup and testing of clinical waste burner with a capability of 75 kg/ hr gas (LPG) total with all accessories and also as a result with the chimney based on the technical specs as well as conditions of public wellness make a space for the incinerator that fit 3 incinerators as in thing 3.1.1 […]
Una cámara de postcombustión de gases * Un quemador de combustión de gases, * Un dispositivo de inyección de aire que permite una recombustión total de gases, * Un dispositivo de entrada de aire de enfriamiento de gases residuales, * Una vaina de evacuación de los gases quemados. * Carcasa en chapa de acero resistente […]
ИНСИНЕРАТОР, ДИЗЕЛЬНЫЙ тип отходов: МЕДИЦИНСКИЕ ОТХОДЫ Теплотворная способность отходов: 4000 ккал / кг Содержание влаги: 10-25% Номинальная мощность: загрузка партии 50 кг / час Вторичная камера: 2 секунды при 850 градусах Цельсия Первичная камера сгорания должна обеспечивать минимальную температуру на выходе не ниже 850 ° C. ИЗОЛЯЦИЯ Силикат кальция Предельный предел непрерывной работы 1000 градусов […]
Burring Capacity 100/ 200 KG/ human resources Please create your offer here Variety of Heater 02 Nos Please write your deal here Incinerator Type Double Chamber Main Chamber Secondy Chamber Please write your offer here Burner Layout Controlled Air Please compose your offer below Gas to be made use of Gas/ Deisel Please write your […]