Basic Info.
Additional Info.
Product Description
The required circular Medical Waste Incinerator is going to be quoted according to Technical Specifications provided below: 1) A self-contained, gas gas, medical waste incinerator with a minimum burn speed capacity of 100 kg/day.
2) A medical waste incinerator shall be specifically designed from the manufacturer to dispose of all Bio-Hazard medical wastes.
3) At a minimum the unit shall be sized to incinerate 2.0 kg/exam-room/24-hrs when being worked continuously for 12 hours every day, however no less than 100kg/day total.
4) The Incinerator shall be batch fed.
5) The incinerator gas tank shall meet the following requirements: A) The tank shall be installed above ground and according to each one the big medical waste incinerator, big portable incinerator, big scale animal incinerator, big scale incinerators for medical waste disposal, fuel tank requirements in Section 1015 including secondary containment. B) The tank shall be sized to hold a 14 day supply of diesel fuel
6) Manufacturer has to supply the following capacity calculations and all supporting information for your incinerator:
– The daily waste flow rate (kg/day or lbs/day) Minimum incinerator burn rate capacities – Minimum cure period for your refractory to protect against breaking into the refractory A comprehensive list of the maintenance components A minimum of 500 pounds of refractory for repairs A minimum of 1 gallon of hydraulic oil
7) The contractor shall provide 3 pricing options: Option 1: To Quotation just for the Full System Option 2: To Estimate the price of Entire System, as well as the Installation Option 3: To give training to appropriate relevant staff according to this ‘Operations and Maintenance. (Afghanistan)
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
2nd. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |