Tag: incineration

Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd. Equipment Technical Specifications Model TS30S Picture   Feed Capacity 78 Liters for Main chamber Burning Rate Typical 30 kgs Each hour Burning Time Each Feed 0.5 hour Voltage 220V Power 0.5Kw Gas Diesel oil Burner Diesel Oil Burner, 2 sets Feed Mode Manual Fuel consumption (Oil) Typical 8 Kgs/Hour External Dimensions 90 x 90 x […]
HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial  trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures,  eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal  for military and civil camps and remote locations where infrastructure is scarce. Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with  other disposal methods. Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid  cross-contamination risk and to keep waste treatment costs at acceptable level. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd..
Items/Model TS75 Picture   Principle Solid Waste Incineration  Burn Rate Average 75 kg/hour Feed Capacity Average 100kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 600L Internal Dimensions 100x60x100cm Secondary Chamber 300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (L/Hour) 15-20 Natural Gas Consumption (m3n/hour) ** Temperature Monitor Digital Screen Temperature […]
The Incinerator units shall be designed to last in operation in a tropical environment for a minimum period of 10 years if the specified maintenance schedule is followed. All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion,Medical waste management pdf. The […]
Waste Disposal Methods in Hospital • An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required.  The automated burn completion and cool down cycle will take place overnight. • The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall […]
Model A1500(Movable platform & Automobile. Picture   Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs/feeding Main Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Gas Form Diesel Oil/ Organic Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) Average 34 kg/hour Gas […]
Items/Model TS1000 Picture   Principle Waste Incineration Treatment Burn Rate Average 1000 kg/hour Feed Capacity Average 3000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter Internal Dimensions 400*120*100 cm Secondary Chamber 1000Liter Feed Mode Manual/Forklift Voltage 220V/380V Electricity 5.0Kw Oil Infection (kg/hour) Average 67(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Screen Temperature Protection Yes Oil […]
Medical Waste Incinerator Capacity: Typical 50-100 kgs Each hour Items/Model TS50(PLC) Picture   Principle Medical Waste Incineration  Burn Rate Average 50-100 kg/hour Feed Capacity Average 100kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Infection (kg/hour) Typical 16.9 Gas […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd. Three Combustion Chambers(Optional) 3 Ranked for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other creature incineration Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Speed (Typical ) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L 2000L 3000L Internal […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  The equipment proposed Will be an incinerator specialised for Medical Wastes.   Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd. Three Combustion Chambers(Optional) 3 Ranked for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other creature incineration Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Speed (Typical ) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control […]