معلومات أساسية. نموذج رقم: تصميم محرقة المستشفى مصادر السحب: معالجة النفايات الصلبة طرق المعالجة: الاحتراق أسواق التصدير: عالمية وصف المنتج تحليلات السوق الدولية لمحرقة النفايات يعطيك. 10 يونيو 2012 تنزيل: تنسيق Word / تنسيق PDF الكلمة الرئيسية: محارق صغيرة محرقة نفايات طبية محرقة حرق جثث الحيوانات الأليفة الشركات المصنعة للمحرقة المحرقة عبارة عن معدات حرق […]
Capacity of destruction in weight: 60 Kg/h. It should be able to operate not less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… Design Specification : Types A, B, C, D, and E of medical waste “PYROLYTIC” combustion, by controlling the gasification of […]
Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber Temperature Monitoring Yes Average ash residue (%) 3% Thermostatic Device Yes 1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards 1) Bidder or Manufacturer ISO 9001 Certified 2) Respecting international emission standards Electrical characteristics 3) A 230V, 60Hz single-phase electrical source. 4) Protections against over-voltage and over-current line conditions. 5) Compliance with applicable Ghanaian standards and regulations. Operational characteristics 6) Two-stage incineration with dual chamber combustion 7) Burn rate: 15 – 20 Kg/h 8) Capacity: not less than 130 L 9) Concentrations of most pollutants in stack gases below detection limits 10) Diesel fuel 11) Electronic system control 12) Easy to operate and minimal training 13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION
we are waste incinerator manufacturers. All waste incinerator design with double combustion chamber. High Temperature, Smoke Treatment,No black smoke, Environmentally friendly. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion […]
Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber Temperature Monitoring Yes Average ash residue (%) 3% Thermostatic Device Yes 1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards 1) Bidder or Manufacturer ISO 9001 Certified 2) Respecting international emission standards Electrical characteristics 3) A 230V, 60Hz single-phase electrical source. 4) Protections against over-voltage and over-current line conditions. 5) Compliance with applicable Ghanaian standards and regulations. Operational characteristics 6) Two-stage incineration with dual chamber combustion 7) Burn rate: 15 – 20 Kg/h 8) Capacity: not less than 130 L 9) Concentrations of most pollutants in stack gases below detection limits 10) Diesel fuel 11) Electronic system control 12) Easy to operate and minimal training 13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION
medical waste incinerator iraq price HICLOVER TS10 PLC 10kgs per hour Items/Model TS10(PLC) Picture Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) average 8.4kg/hour Gas […]
wea are chinese incinerator manufacturers. Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. All series included burning capacity 10kgs per hour, 30kgs per hour,50kgs per hour,100kgs per hour,150kgs per hour,300kgs per hour,500kgs per hour. Up to now, all models sale to all over the world and have good feedback […]
Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste. HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/ Email: [email protected]Email: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 2020-07-21