it’s also very important for us to know whether the unit is qualified to deal with cytotoxic waste and also the characteristics and disposal of treatment residues. Moreover, operational needs in terms of electricity and fuel consumption, as well as especially the off-gas treatment system implemented, bear significant importance, as fulfilling the requirements of Regulation […]
Medical waste is posing a growing problem all around the world, jeopardizing the health of staff, patients, disposal employees and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this broad range […]
HIGH TECH PYROLYTIC MEDICAL WASTE INCINERATOR 1. 21. The de- ashing must be performed in the bottom of the combustion chamber or the deashing Electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating * A timer with flexible temporization for the regulation of every burner. * Carcass in solid sheet steel with support […]
Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with other disposal methods.Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. — Upgrade/Downgrade Burning Rate WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. ※Main Feature:–Three Combustion Chambers or A/B Main Combustion Chamber— Double or Three Italy Burner–Burning Rate: 80-800kgs per hour–Combustion Chamber: 1.0M3-10.0M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Semi-Automatic Waste Feeding— 3-Section Wet Scrubber System— Movable Platform Feeding Door— Additional Burner Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: [email protected]Email: [email protected] Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L […]
Quantity: Two [2] with complete accessories. Kinds of wastes being used: GENERAL WASTE.Polyester, polypropylene, polystyrene, vinyl acetate plastic, synthetic plastics, – Assumption: general hospital beds 50 percent, surgery beds 50% for the 100 bed hospital instance, while this ratio is 30-70% for the other cases * Frontage of loading door seals gone up on hinges, […]
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We provide single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, […]
Automatic loading and reloading with capacity of 10 to 12 tons per day working with gas treatment procedures and gasoline fuel and should comply with the European Standards.the Government Hospital for Medical Waste Incinerator with these Specifications. They’re having general wastes like cells, plastic bottles ,wastes coming from labour camps, to be incinerated, they want, […]
Key Features: General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.— Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.— System solutions for medical waste environmental.— High burn rate, from 5kgs to 1000kgs per hour.— New Design for pet animal cremation business. — HICLOVER, trusted partner with years of experience. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: [email protected]Email: [email protected] Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L […]
13. Civil works, installation and Comnuss!Onmg lndusive of civil works (brick wall incinerator house Type of waste for disposal Animal body parts,other biomedical waste,organs dung, bedding materials,plant p缸ts and meals itemsι bidding document 51. No Features $_pecific tions 6. 11. Opening lid Large top open归g lid (Approx. 700 mm x 500mm) for […]
— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — System solutions for medical waste environmental. — High burn rate, from 5kgs to 1000kgs per hour. — New Design for pet animal cremation business. — HICLOVER, trusted partner with years of experience. Nanjing Clover Medical Technology Co.,Ltd.. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary […]