Category: Uncategorized

Waste incineration technology sprouted in the late 1800s. Since the 20th century, with the development of greatly improved and incineration of municipal waste production, waste incineration has become in many countries to develop waste treatment technology. Garbage incinerator waste incineration is the core technology. Early incinerators by coal-fired boiler manufacturing factory, does not apply to […]
The idea is good . There toss volcano every day, it appears to be an ideal natural elimination of garbage incinerator. However, I know you want to, but that there is kind of the center of the crater lake of lava lovely. Like some of the shield volcano in Hawaii, they will spray lava slowly […]
Biomedical Waste Incinerator, 10-15 kg Manufacturer: Brand: Type / Model: Country of Origin: Description of Function The Biomedical Waste Incinerator is used for Incineration of each type of Biomedical Waste. The Disposal of such Biomedical waste is a very important as it is a dangerous wastes for human life, and It is only possible with a perfect incinerator. Operational Requirements It shall be operated by manual and automated mode. The combustion efficiency (CE) shall be at least 99.00%. The combustion efficiency is computed as follows: C.E.= __%CO2______ x 100 %CO2 + %CO Emission Standards: Lower emission rates are preferred. Parameters                   Concentration in mg/Nm3 (12% CO2 correction Max total dust              30mg/m3 Max Sulphur Dioxide      200mg/m3 Max Nitrogen dioxide    400mg/m3 Max Carbon                     100mg/m3 Monoxide Minimum stack height shall be 30 metres above ground. Volatile organic compounds in ash shall not be more than 0.01%. System Configuration Biomedical Waste Incinerator, complete unit. Technical Specifications Incinerator: It shall be Electrical or Diesel Fired Incinerator or Controlled Air & pyrolytic. Type of Waste: Biomedical Waste It shall have burning capacity 10-15 kg/hr. Fuel: Diesel Burner: Monoblock fully automatic burners. Temperature: Primary Chamber 800 ± 50 oC, Secondary Chamber 1050 ± 50 oC. Type of Waste: Biomedical waste with moisture content up to 85%. Destruction Efficiency: 99%. It shall have separate digital display of temperature for both chambers. It shall have provision for measuring primary & secondary chamber temperatures using external thermo coupler. Secondary chamber gas residence time shall be minimum 1 second at 1050 oC. Primary Chamber: Type: Static Solid Hearth Material of Construction: Mild Steel, 5mm thick Refractory thickness: approx.115mm thick Material: Refractory bricks confirming to international standard. Temperature resistance: 1400 oC Insulation thickness: approx.115mm thick Material: Insulation bricks confirming to international standard. Waste Charging: Manual & Automatic waste charging. Ash Removal: Manual/automatic Secondary Chamber: Type : Static Solid Hearth Material of Construction: Mild Steel, 5mm thick Refractory thickness: approx.115mm thick Material: Refractory bricks confirming to international standard. […]
Items/Model TS30(PLC) TS50(PLC) Burn Rate 30 kg/hour 50 kg/hour Feed Capacity 60kg 100kg Control Mode PLC PLC Combustion Chamber 330L 560L Internal Dimensions 75x75x60cm 100x80x70cm Secondary Chamber 180L 280L Smoke Filter Chamber Yes Yes Feed Mode Manual Manual Voltage 220V 220V Power 0.5Kw 0.7Kw Oil Consumption (kg/hour) 10.2–20 12.1–24 Gas Consumption (m3/hour) 9.8–20 9.9–26.1 Temperature […]
VietNamNet Bridge – While Vietnamese made medical and domestic waste incinerators are finding it difficult to enter the commercial market, foreign-made incinerators have been imported in great numbers. Vinh Phuc, Phu Tho, Nam Dinh, Thai Binh and Bac Giang provinces have all imported small-scale incinerators to treat domestic waste The outdated equipment is unsuited to […]
Clover Incinerator update A model incinerator for pet cremation and animal incineration. New design accept independent movable platform in-out incinerator combustion chamber. This new design is valid for model A900 and bigger model. Tel:  +86-25-8461 0201       Email:  [email protected]     Email:  [email protected]
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World. Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local  manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. to 600kgs/Hr., up […]
We supply small scale waste incinerator with cheaper price, the burning rate for medical waste with 10/20/30/50kgs per hour. Model YD-10C/YD-20C/YD-30C/YD-50C, contact with us now:   [email protected] * cheaper price *double combustion chamber *stainless steel chimney *for small pet cremation  
New Incinerator ready for shipping, the model is TS50 and below photo is combustion fire test in factory. *Doubel Chamber Incinerator *Diesel Oil Direct Fire Incinerator