Carburant Diesel Capacité (M3) 1.92 Ave Capacity 1200kg Consommation (litre/heure 12 Dimension externes Longueur (mm) 3110 Largeur (mm) 2150 Hauteur (mm) 3200 Ouverture Porte 1000×2000 Dimension internes Longueur (mm) 2200 Largeur (mm) 1050 Hauteur (mm) 800 Opération Minimum température d’opération 950 Maximum température d’opération 1320 Température de suivi oui Thermostat oui Ventilateur oui Chambre de […]
COMPLIANCE (YES, NO or COMMENT) Item Description Medical Waste Incinerator, 50 to 60 Kg/hr Item Quantity 5 No. Support Health Sector Support Project Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals 1. General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal […]
COMPLIANCE (YES, NO or COMMENT) Item Description Medical Waste Incinerator, 100 to 120 Kg/hr Item Quantity 3 No. Support East African Networking Project Point of Installation (Hospitals) Wajir, Kitale, and Busia District Hospitals General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General […]
incenratory Gilgit-Baltistan Environmental Protection Agency intends to mange hospital waste through piloting of three major districts headquarter hospitals (Hunza/Nagar, Skardu, Chillas and Gilgit and city hospital Gilgit) through integrated Solid/Biomedical Waste management. For this purpose GBEPA has planned to procure solid/biomedical waste incinerators with other necessary equipment through open competitive Single stage (two envelop […]
TABLE OF CONTENTS OBJECTIVE OF THE PROGRAMME 4 STRUCTURE OF THE PROGRAMME 4 COLLABORATORS INVOLVED IN THE PROGRAMME 4 STAKEHOLDERS INVOLVED IN THE PROGRAMME 4 LABORATORY TRIALS 5 FIELD TRIALS 13 1. OBJECTIVE OF THE PROGRAMME The objective of the programme is to select technical criteria suitable for tender specification purposes […]
Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Standards 1) Bidder or Manufacturer ISO 9001 Certified […]
Description Minimum Requirements Design standard Multiple chamber incinerator to the design of EPA standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: • Length • Width • Height • Extra width for burners At least 3000mm Loading […]
INCINERATOR (WASTE INCINERATOR) Designed to burn disposables that can and should be destroyed on-site. Theses wastes include infectious and contaminated “red bag.” Surgical dressings, plastic test devices and other wastes Fast, complete, efficient waste disposal Dual chamber combustion, Chambers insulated and lined with high temperature refractory. Programmable digital temperature controls, temperature indicators and charge recorder. […]
1) minimum with a burning area (kiln) of at least 2.8 m3 (KG/Hour is not the driving factor) 2) Large – Must reach 1300 degree temperature or higher and approved for medical waste burning and be capable of burning > 4 m3 of materials at one time (the Hurikan 500 incinerator model or equivalent). – […]
SPECIFICATIONS OF THE MEDICAL/BIOLOGICAL WASTE INCINERATOR It should be a three chambered incinerator The load capacity of 250 kg The housing for the incinerator should be able to withstand the temperatures and other operational requirements. The chimney should have a strong refractory lining of special type of cement to withstand temperatures more than 1200o It […]