Equipped with main combustion chamber and a second chamber for reburning designed to ensure complete
combustion of the gases resulting from incomplete combustion of inert gases in the chimney, within the standards
recommended by the World Health Organization;
- Equipped with temperature controller to adjust the air of the combustion of the waste, and fuel flow in the
burners of the firing chamber and re-burning in order to conserve power when reached the “stead state” of the
combustion process;
- The control system must also be provided with an audible alarm in case of decrease in temperature. The
characteristic of local power is three-phase 220/127V – 60Hz.;
- The natural circulation of the gases will be induced in a chimney height at least 6 meters and diameter of
at least 40 centimeters, so that negative pressure is sufficient to protect the operator from excess of fires or
dispersion of noxious gases;
- Supplied with electrical control panel with thermo-magnetic protection and command buttons; and,
- Equipped with pyrometers meters/controller of thermocouple temperature with chromium-aluminium,
range 0-1200 Deg C (to observe the temperature of the first and