Technical Specifications Pre-assembled, containerized type —yes, do not included chimney installation. Burning rate: 100 – 120kg / hour —yes Minimum operating temperature: 8500c (Primary combustion) —800-1000 degree Maximum operating temperature: 14500c (afterburner chamber) —1000-1200 degree Secondary Burning capacity: Compulsory. —yes Density insulation: 20 mm high —50mm Refractory casting: minimum […]
Capacity UPTO 20 kg/hr Size: 940 x860x2700 mm Material: STAINLESS STEEL STACK, REFRACTORY CONCRETE LINING SPECIAL INSULATION MATERIAL With burner: 15 – 20 KW Temperature: PRIMARY CHAMBER = 800°C AND SECONDARY CHAMBER = 850 – 1200° C Sufficient heat generation for secure and complete combustion 600-800 °C in the first chamber and >1000 °C in […]
Carburant Diesel Capacité (M3) 1.18 Ave Capacity 750 kg Consommation (l/h) 6 Dimension externes Longueur (mm) 3110 Largeur (mm) 1800 Hauteur (mm) 3300 Ouverture Porte 770×2000 Dimension internes Longueur (mm) 2100 Largeur (mm) 700 Hauteur (mm) 800 Opération Minimum température d’opération 950 Maximum température d’opération 1320 Température de suivi oui Thermostat oui Ventilateur oui Chambre […]
Carburant Diesel Capacité (M3) 1.92 Ave Capacity 1200kg Consommation (litre/heure 12 Dimension externes Longueur (mm) 3110 Largeur (mm) 2150 Hauteur (mm) 3200 Ouverture Porte 1000×2000 Dimension internes Longueur (mm) 2200 Largeur (mm) 1050 Hauteur (mm) 800 Opération Minimum température d’opération 950 Maximum température d’opération 1320 Température de suivi oui Thermostat oui Ventilateur oui Chambre de […]
COMPLIANCE (YES, NO or COMMENT) Item Description Medical Waste Incinerator, 50 to 60 Kg/hr Item Quantity 5 No. Support Health Sector Support Project Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals 1. General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal […]
COMPLIANCE (YES, NO or COMMENT) Item Description Medical Waste Incinerator, 100 to 120 Kg/hr Item Quantity 3 No. Support East African Networking Project Point of Installation (Hospitals) Wajir, Kitale, and Busia District Hospitals General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General […]
incenratory Gilgit-Baltistan Environmental Protection Agency intends to mange hospital waste through piloting of three major districts headquarter hospitals (Hunza/Nagar, Skardu, Chillas and Gilgit and city hospital Gilgit) through integrated Solid/Biomedical Waste management. For this purpose GBEPA has planned to procure solid/biomedical waste incinerators with other necessary equipment through open competitive Single stage (two envelop […]
TABLE OF CONTENTS OBJECTIVE OF THE PROGRAMME 4 STRUCTURE OF THE PROGRAMME 4 COLLABORATORS INVOLVED IN THE PROGRAMME 4 STAKEHOLDERS INVOLVED IN THE PROGRAMME 4 LABORATORY TRIALS 5 FIELD TRIALS 13 1. OBJECTIVE OF THE PROGRAMME The objective of the programme is to select technical criteria suitable for tender specification purposes […]
Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Standards 1) Bidder or Manufacturer ISO 9001 Certified […]
Description Minimum Requirements Design standard Multiple chamber incinerator to the design of EPA standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: • Length • Width • Height • Extra width for burners At least 3000mm Loading […]