pet waste incinerator manufacturer


Technical requirements for shedding gadget, animal waste incinerator supplier
1. 2 systems are required to be mounted in the south of the Kingdom of Saudi Arabia. Both systems will be utilized by tailored authority to melt various kind of medications. All need gadgets require to be given.
2. Warranty: booth systems need to be supplied 3 years service warranty from the day of approval. All called for extra components, preventative maintenance repair work as well as likewise corrective upkeep demand to be consisted of in the price as well as supplied to the client.
3. All needed electric in addition to water links need to be offered.
4. Both systems need to be of superior quality as well as must be ecological friendly.
5. The ability of each system need to be up to 100 kg/hr.
6. The system has to have actually automated feeding.
7. Each system needs to includes two melting areas, one primary area for melting the medication and additionally another room for melting the gases that release as an outcome of major burning.
8. The oven should be created from steel that is rust resistance and with density not less than 6 mm.
9. Each system needs to be of high trusted in shedding various kind of medicines, and also should certainly have 99.9% effectiveness for melting natural products.
10. Waste items need to not go beyond 5%.
11. System needs to have automated ignition system.
12. System requires to use diesel (HSD) as gas and should not consume greater than 8 to 10 lt/hr.
13. Each system ought to be given with fuel storage tank of measurement appropriate to run the system for one total day.
14. The temperature level in the primary area must be 850 C ± 50 C. the system require to additionally be qualified to operate as long as 1050 C ± 50 C. the system should can proceeds procedure in addition to needs to be supplied with concrete layer insulator with proper thickness.
15. Stove ought to be offered with cozy insulator to permit simple operation.
16. Gas should certainly stay in the additional location for not above 1.5 second.
17. The primary burning area have to contend the very least 2 heating systems.
18. The 2nd burning location require to have one heating system.
19. Each system must have doors for ash, leave for air to the smokeshaft and also windows to allow looking inside as well as for upkeep.
20. Each system must have filtering system for gas handling with 2 tanks utilizing average water. Each water container need to have capacity of 1000 lt and should certainly be repaired to the system in addition to provided with water degree sign.
21. Each system has to have unique technology for dividing waistline items and additionally humidity after gas handling.
22. Each system requires to have cooling off capability after treatment.
Each system m should be supplied with exhaust pipe with 250 mm size and also 10 m high. The base of the exhaust system ought to be 1000 mm. The exhaust system should be provided with stress indicator.
24. Electric power: require to be 220 volt, 3 phase, 60 Hz, as well as the electric motor needs to not be much less than 15 HP.
25. Each system has to be supplied control panel and also signs as well as required protection devices as well as alarm. The control panel ought to expose at the very least temperature degree in both the secret as well as added locations and additionally injectors of the filters as well as additionally tons.
26. Each system should certainly be provided with safety and security system for any break down or issue of any type of type of part of the system.
27. The following individual safety tools have to be offer:
a.Heat immune garments for 20 people.
b.Heat immune goggles for 20 persons.
28. All elements of each system should be painted with silver color that is warmth resistant.